Products
Shielding / Screen for 24 kV and 36 kV Bushing types specially produced according to design
Shielding or screens for 24 kV and 36 kV bushings are specially designed components used primarily as field regulators within medium-voltage transition products. They are typically made from brass, stainless steel or aluminum, ensuring durability and effective performance in electrical insulation and protection applications.
Inner conductor contacts for 24 kV and 36 kV Plug-in type Bushings
Inner conductor contacts for 24 kV and 36 kV plug-in type bushings are specially manufactured to ensure seamless current transmission in medium-voltage transition products. They enable tight contact between two conductors, ensuring reliable electrical connectivity and efficient performance.
Safety covers for 24 kV and 36 kV Bushing types
Safety covers for 24 kV and 36 kV bushing types are used in medium-voltage transition products to protect critical components from external physical damage. Typically made from plastic or rubber, they provide durable protection, ensuring the longevity and safety of the equipment.
Cap nuts used in the manufacture of resin-based insulators
Cap nuts are used in resin-based insulators, such as those made from epoxy resin, are essential for mounting current and voltage transformers, as well as securing insulators. They also serve to fasten busbars to the insulators or transformers. Typically made from brass, aluminum or metal, these nuts ensure secure and stable installation.
Flexible busbar
A flexible busbar conducts electricity between moving or fixed parts. Made from copper wire or sheets, it provides high flexibility and conductivity. Copper is often coated with metals like silver or tin to enhance performance and prevent corrosion. Ideal for high-current and power systems.
Low voltage torodial current transformers
Low Voltage Toroidal Current Transformers measure electric currents in low-voltage systems. Operating on electromagnetic induction, they deliver accurate measurements with low power loss and are commonly used in energy monitoring and load balancing applications.
Cable clamp
Cable clamps facilitate the passage of electrical cables through walls, floors, or structural surfaces. They ensure that cables are securely and neatly arranged, providing protection against external factors while allowing for watertight installation. These clamps are essential for maintaining order in cable management.
Cell cable entry boots
Cell cable entry boots are a type of seal used to protect cable passages and ensure sealing within cell structures. These boots are commonly used in electrical equipment such as switchgear, control cabinets, and transformer substations, providing both protection and insulation for cable entries.
Mold Release Oils
Mold Release Oils facilitate the easy separation of products from molds. They keep molds cleaner by preventing residue buildup and enhance the visual quality of finished products, resulting in smoother surfaces and improved aesthetics. Overall these oils contribute to more efficient production and higher-quality results.
Wheels for transformers
Wheels for transformers are typically made from cast iron. These wheels play a crucial role in facilitating the movement of the transformer, allowing it to be easily shifted when necessary. This mobility is especially useful during installation, maintenance, or repositioning tasks in transformer systems.
Moisture holders
It is a product mounted on the expansion tank of transformers to prevent direct contact between the oil and the atmosphere. Filled with silica gel, it protects the oil from moisture and dust contamination. The product is manufactured in various connection methods, tailored to the operating conditions of the transformer.
Pressure safety valves and Protection relays
Bimetal thermometers measure oil temperature in transformers and include electronic switches with maximum and minimum indicators for control system integration. Made from bimetal materials, they ensure reliable performance in all temperatures. Pressure relief valves prevent transformers from being damaged by excessive pressure.
Arc horn and Fixing elements for all Bushing types
Connection and fixing elements for all bushing types are used to securely mount medium-voltage transition insulators to products. Made from aluminum, stainless steel, or metal, these components ensure safe installation and ease of assembly, providing stability and reliability in electrical systems.
Busbar Contacts used in the production of resin-based ins.
Busbar contacts are crucial components in transition insulators, as they enable the primary function of current transmission. Both the production and design processes play an equally important role in ensuring their performance. These precision components, typically made from copper or aluminum, are often coated with tin or silver for enhanced conductivity and protection.
Ceramic capacitor
Ceramic capacitors are used in voltage divider insulators to segment voltage. Their ceramic composition requires careful handling, and they help indicate voltage levels for safety. Partial discharge and capacitance testing are crucial due to their long-term use under medium voltage.
Core cover
The core cover is essential during transformer casting, providing protection for the core against external impacts and damage from resin shrinkage. Made from durable plastic, it acts as a shield to maintain the core’s integrity during and after the casting process, ensuring long-term performance and reliability of the transformer.
Cable entry gland
A cable gland refers to the equipment or structural element that allows high-voltage electrical cables to pass through a building or structure. These glands emphasize specific capacities and play a crucial role in overcoming technical challenges in cable laying projects, ensuring secure and safe cable entry.
Load break switch and circuit breaker gaskets
Load break switch and circuit breaker gaskets are made from rubber or elastomeric materials to seal between surfaces. They fill gaps between connected parts to prevent liquid or gas leaks in pressurized systems, ensuring a tight seal that maintains the system’s efficiency and safety.
LV output busbars for transformers
LV output busbars are used in the low-voltage outputs of distribution transformers. They are typically made from materials like brass casting or machined brass copper. Coatings can be applied as needed to enhance performance, providing durability and longevity, especially in outdoor environments.
Butterfly valves
Butterfly valves are used to control the flow of fluid between the transformer tank and the radiator. They are manufactured either welded or unwelded according to the user’s design. Various head options such as locking cap, locking lever, standard head device, and arm are offered to the consumer.
Oil level indicators
The oil level indicator provides information about the amount of oil inside the transformer. It is produced in various sizes and connection types, including float ball, vertical float, vertical magnetic, and horizontal magnetic, depending on the specific application requirements.
Connection pipes, Oil drain devices and Thermometer pockets
Oil drain valves enable the draining of oil by connecting to a special device and utilizing a suitable mechanism. These valves assist in the discharge of oil. Thermometer pockets are used in conjunction with bimetal thermometers to measure the oil temperature inside the transformer.
Need Help with Easier Industrial Solutions? We Are Experts!
Click here to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.